About 30,500 results
Open links in new tab
  1. How to Reset the Flame Rollout Switch on a Carrier Furnace - Expert …

    To reset the flame rollout switch on a Carrier furnace, first turn off power and gas. Locate the switch near the burner assembly; it looks like a small button or sensor.

  2. Carrier Furnace Blower Reset: Expert Q&A & Troubleshooting Guide

    To reset the Carrier FB4CNF030 blower, first turn off power at the thermostat and breaker. Locate the blower compartment panel—usually on the furnace’s front lower section—and remove it. Find the …

  3. Expert Solutions for Furnace and Boiler Limit Switch Issues ...

    I have a ~25 year old Carrier 58DHB furnace and the limit switch kept tripping out over the last year or more. We How to reset limit switches on a Carrier furnace?

  4. Reset Flame Rollout Switch: Expert Help & Troubleshooting Guide

    Customer: Hello I need to reset the flame rollout switch. Optional Information: Make : carrier Model : ck5bxa0600z4aaaa Already Tried: i have determined LED code 13. The blower is continually …

  5. Expert Solutions for Carrier Gas Furnace Draft Safeguard Switch Issues

    My gas furnace is a Carrier. The draft safeguard switch keeps tripping and needs to reset for the start the furnace.

  6. Carrier Furnace Flame Rollout Switch Reset Help – Q&A Guide

    The HVAC Technician can help with resetting the flame rollout switch on your Carrier furnace. And, how would you like to connect with the Technician - phone call or online chat?

  7. Carrier Furnace Error 13 Limit Lockout? Troubleshooting Help

    This code indicates that the furnace has overheated, causing the limit switch to activate. Your system contains two types of limit switches: one that can be reset using the breaker and another that can be …

  8. Reset Limit Switches on Carrier Furnace: Expert Help & Guide

    Carrier Furnace Code 33: Resetting Limit Switches Guide Limit switches often trip due to overheating or airflow restrictions causing furnace shutdowns. To reset limit switches on a Carrier furnace showing …

  9. Carrier Furnace Error Code 33: Expert Troubleshooting & Reset Guide

    The technician has come out and "reset the switch" twice this summer. That's all I'm trying to achieve. Which switches need to be reset and where can I find them? Carrier code #33 while running the AC …

  10. Carrier Weathermaker 8000 Troubleshooting: Limit Switch, Reset …

    I have a Carrier Weathermaker 8000 gas furnance and the LED is flashing code 33 (Limit or flame roll-out switch is open).